Update: Battery Optimizer v3.4.0 mit allen Fixes und Features
This commit is contained in:
98
legacy/v2/ENTITY_CHECKLIST.md
Normal file
98
legacy/v2/ENTITY_CHECKLIST.md
Normal file
@@ -0,0 +1,98 @@
|
||||
# ✅ Entitäten-Checkliste
|
||||
|
||||
## Nach Installation sollten folgende Entitäten existieren:
|
||||
|
||||
### Input Boolean (2 Stück)
|
||||
- [ ] `input_boolean.battery_optimizer_enabled`
|
||||
- [ ] `input_boolean.battery_optimizer_manual_override`
|
||||
|
||||
### Input Number (7 Stück)
|
||||
- [ ] `input_number.battery_capacity_kwh`
|
||||
- [ ] `input_number.battery_optimizer_min_soc`
|
||||
- [ ] `input_number.battery_optimizer_max_soc`
|
||||
- [ ] `input_number.battery_optimizer_max_charge_power`
|
||||
- [ ] `input_number.battery_optimizer_price_threshold`
|
||||
- [ ] `input_number.battery_optimizer_reserve_capacity`
|
||||
- [ ] `input_number.battery_optimizer_pv_threshold`
|
||||
|
||||
### Input Text (1 Stück)
|
||||
- [ ] `input_text.battery_optimizer_status`
|
||||
|
||||
### Template Sensors (3 Stück) - werden AUTOMATISCH erstellt
|
||||
Diese Sensoren werden erst nach Home Assistant Neustart und Laden der Templates erstellt:
|
||||
- [ ] `sensor.battery_charging_plan_status`
|
||||
- [ ] `sensor.battery_next_action`
|
||||
- [ ] `sensor.battery_estimated_savings`
|
||||
|
||||
**Hinweis:** Template Sensors zeigen "unavailable" bis der erste Plan berechnet wurde!
|
||||
|
||||
### PyScript States (1 Stück) - wird AUTOMATISCH erstellt
|
||||
Dieser State wird beim ersten Aufruf von `calculate_charging_schedule()` erstellt:
|
||||
- [ ] `pyscript.battery_charging_schedule`
|
||||
|
||||
### Bestehende Entitäten (müssen bereits vorhanden sein)
|
||||
- [ ] `input_boolean.goodwe_manual_control` (dein bestehendes System)
|
||||
- [ ] `input_number.charge_power_battery` (dein bestehendes System)
|
||||
- [ ] `sensor.openems_ess0_soc` (OpenEMS Modbus)
|
||||
- [ ] `sensor.hastrom_flex_pro` (Strompreis-Sensor)
|
||||
- [ ] `sensor.energy_production_today` (Forecast.Solar Ost)
|
||||
- [ ] `sensor.energy_production_today_2` (Forecast.Solar West)
|
||||
- [ ] `sensor.energy_production_tomorrow` (Forecast.Solar Ost)
|
||||
- [ ] `sensor.energy_production_tomorrow_2` (Forecast.Solar West)
|
||||
|
||||
## Prüfen nach Installation
|
||||
|
||||
### Schritt 1: Input Helper prüfen
|
||||
```
|
||||
Einstellungen → Geräte & Dienste → Helfer
|
||||
```
|
||||
Suche nach "battery_optimizer" - sollte 10 Einträge zeigen
|
||||
|
||||
### Schritt 2: Template Sensors prüfen
|
||||
```
|
||||
Entwicklerwerkzeuge → Zustände
|
||||
```
|
||||
Suche nach "battery_" - Template Sensors sollten existieren (können "unavailable" sein)
|
||||
|
||||
### Schritt 3: Ersten Plan berechnen
|
||||
```
|
||||
Entwicklerwerkzeuge → Dienste
|
||||
service: pyscript.calculate_charging_schedule
|
||||
```
|
||||
|
||||
### Schritt 4: PyScript State prüfen
|
||||
```
|
||||
Entwicklerwerkzeuge → Zustände
|
||||
```
|
||||
Suche nach "pyscript.battery_charging_schedule" - sollte jetzt existieren!
|
||||
|
||||
### Schritt 5: Template Sensors sollten jetzt Werte haben
|
||||
```
|
||||
Entwicklerwerkzeuge → Zustände
|
||||
```
|
||||
- `sensor.battery_charging_plan_status` sollte z.B. "3 Ladungen geplant" zeigen
|
||||
- `sensor.battery_next_action` sollte nächste Aktion zeigen
|
||||
- `sensor.battery_estimated_savings` zeigt Ersparnis (oder 0)
|
||||
|
||||
## Fehlende Entitäten beheben
|
||||
|
||||
### Wenn Input Helper fehlen:
|
||||
1. Prüfe ob `battery_optimizer_config.yaml` richtig in `/config/packages/` liegt
|
||||
2. Prüfe ob in `configuration.yaml` Packages aktiviert sind:
|
||||
```yaml
|
||||
homeassistant:
|
||||
packages: !include_dir_named packages
|
||||
```
|
||||
3. Home Assistant neu starten
|
||||
4. Logs prüfen auf Fehler
|
||||
|
||||
### Wenn Template Sensors fehlen:
|
||||
1. Prüfe ob der `template:` Abschnitt in der Config ist
|
||||
2. Home Assistant neu starten
|
||||
3. Yaml-Konfiguration prüfen in Developer Tools
|
||||
|
||||
### Wenn PyScript State fehlt:
|
||||
1. PyScript muss installiert sein
|
||||
2. `battery_optimizer.py` muss in `/config/pyscript/` sein
|
||||
3. Dienst `pyscript.calculate_charging_schedule` manuell aufrufen
|
||||
4. Logs prüfen auf Fehler
|
||||
Reference in New Issue