Update: Battery Optimizer v3.4.0 mit allen Fixes und Features
This commit is contained in:
45
legacy/v1/battery_optimizer_rest_commands.yaml
Normal file
45
legacy/v1/battery_optimizer_rest_commands.yaml
Normal file
@@ -0,0 +1,45 @@
|
||||
# ============================================
|
||||
# Battery Charging Optimizer - REST Commands
|
||||
# ============================================
|
||||
# Diese REST Commands zu deiner configuration.yaml hinzufügen
|
||||
|
||||
rest_command:
|
||||
# ESS in REMOTE Mode setzen (für manuelles Laden via HA)
|
||||
# WICHTIG: Muss VOR dem Schreiben auf Register 706 aufgerufen werden!
|
||||
set_ess_remote_mode:
|
||||
url: "http://x:admin@192.168.89.144:8074/jsonrpc"
|
||||
method: POST
|
||||
payload: '{"method": "updateComponentConfig", "params": {"componentId": "ess0","properties":[{"name": "controlMode","value": "REMOTE"}]}}'
|
||||
content_type: "application/json"
|
||||
|
||||
# ESS in INTERNAL Mode setzen (zurück zu automatischem Betrieb)
|
||||
# WICHTIG: NACH dem Laden aufrufen, um wieder auf Automatik zu schalten!
|
||||
set_ess_internal_mode:
|
||||
url: "http://x:admin@192.168.89.144:8074/jsonrpc"
|
||||
method: POST
|
||||
payload: '{"method": "updateComponentConfig", "params": {"componentId": "ess0","properties":[{"name": "controlMode","value": "INTERNAL"}]}}'
|
||||
content_type: "application/json"
|
||||
|
||||
# Alternative: Modbus Write über Home Assistant Modbus Integration
|
||||
# (Bevorzugte Methode für dynamische Werte)
|
||||
|
||||
# Füge diese Modbus-Konfiguration hinzu wenn noch nicht vorhanden:
|
||||
modbus:
|
||||
- name: openems
|
||||
type: tcp
|
||||
host: 192.168.89.144
|
||||
port: 502
|
||||
|
||||
# Write-Register für Batterieleistung
|
||||
# Register 706: ess0/SetActivePowerEquals
|
||||
# FLOAT32 Big-Endian - Negativ = Laden, Positiv = Entladen
|
||||
|
||||
# Optional: Sensor zum Lesen des aktuellen Sollwerts
|
||||
sensors:
|
||||
- name: "OpenEMS Batterie Sollwert"
|
||||
address: 706
|
||||
data_type: float32
|
||||
swap: none # Big-Endian
|
||||
scan_interval: 30
|
||||
unit_of_measurement: "W"
|
||||
device_class: power
|
||||
Reference in New Issue